Dansons-group GLOW BOY IGB Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Dansons-group GLOW BOY IGB. Dansons Group GLOW BOY IGB User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TM
Classic Insert / Built-In
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR HEATER.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH!
Installation shall conform to CAN/CSA B365 Installation Code for Solid-Fuel-Burning Appliances and
Equipment in Canada and NFPA 211 Chimney, Fireplaces, Vents and Solid Fuel Burning Appliances in th e USA
.
Contact local building or fire officials about restrictions and installation inspection requirement s in your area.
Toll Free Technical Support
1 - 866 - GLOWBOY (456 -9269)
To register your purchase
www.dansons.com/support
Memory & Fan Trim
or
Step Top
Freestanding
Bay View
Freestanding
Bay View
Insert / Built-In
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Toll Free Technical Support

TMClassic Insert / Built-InREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR HEATER.FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DA

Page 2 - Glow Boy

10 PPLANNINGLANNING——EEXHAUSTXHAUST SSYSTEMSYSTEMS PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES

Page 3

11 PPLANNINGLANNING—— EEXHAUSTXHAUST SSYSTEMSYSTEMS … … CONTINUEDCONTINUED DETERMINE VENTING SIZE AND DISTANCE: It is recommended that the ven

Page 4 - RECAUTIONS

12 PPLANNINGLANNING—— EEXHAUSTXHAUST SSYSTEMSYSTEMS … … CONTINUEDCONTINUED PELLET VENT TERMINATION: (Figures 7 & 8) Termination must be a min

Page 5

13 PPLANNINGLANNING—— OOUTSIDEUTSIDE AAIRIR Outside air is REQUIRED ON ALL MOBILE HOME INSTALLATIONS. Outside air is strongly recommended for all

Page 6 - FUEL CONSIDERATIONS

14 PPLANNINGLANNING—— PPROTECTIONROTECTION & C& CLEARANCESLEARANCES STOVE PLACEMENT: FLOOR PROTECTION REQUIREMENTS: MINIMUM CLEARANCES T

Page 7 - AcuTron Wiring Harness

15 16”PPLANNINGLANNING—— PPROTECTIONROTECTION & C& CLEARANCESLEARANCES . . . C. . . CONON’’TT CLEARANCES – “CORNER INSTALLATION”:

Page 8 - PECIFICATIONS

16 TTOOLSOOLS RREQUIREDEQUIRED Power Tools Shop Vacuum WITH Filter Jigsaw or Reciprocating saw Electric drill Extension cord 4” or 5” di

Page 9

17 IINSTALLATIONNSTALLATION——FFREESTANDINGREESTANDING THROUGH THE WALL, DIRECT VENT INSTALLATION. (not preferred) (Figure 18) 1.

Page 10 - VENT SAFETY PRECAUTIONS:

18 MMOBILEOBILE HHOMEOME IINSTALLATIONNSTALLATION CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MANUFACTURED H

Page 11 - CONTINUED

19 Walkout Basement or Main FloorBasement or Main Floor1Pipe AdapterClean Out Tee & CapTee Support BracketHorizontal Rain Cap234567890 Deg Elbow3

Page 12

2 Glow Boy Pellet & Biomass www.glowboystoves.com 2 Friendly Reminder: A pellet stove / insert is not design

Page 13

20 FFIREPLACEIREPLACE IINSERTNSERT IINSTALLATIONNSTALLATION 2Main Floor - Tie-In Claytile Flue1“PL” Pipe AdapterSingle Wall Stainless SteelCl

Page 14 - NTERIOR ERTICAL

21 Installing Pellet Inserts into Factory Built or Masonry Fireplaces . . . cont Means must be provided for removal of the insert to clean the c

Page 15 - A - T T

22 CAUTION: DO NOT BLOCK ANY VENT OPENINGS PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE. (INSTALL VENT AT CLEARANCES S

Page 16 - Hand Tools

23 Glow Boy Pellet & Biomass www.glowboystoves.com 23 8”6”Wall Band / Support Brktevery 5’Wood FrameCons

Page 17 - REESTANDING

24 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS COMPLETE THE CHECK LIST (Page 9) PRIOR TO LIGHTING YOUR FIRST FIRE FOLLOW THE ARROWS TO START YOUR

Page 18 - HEARTH PAD

25 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS FILL THE HOPPER WITH FUEL: Open the hopper lid by placing your fingers in the recessed handle on t

Page 19

26 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS IMPORTANT: If at anytime your appliance does not seem to be operating as it had,

Page 20 - Main Floor - Class A Tie-In

27 OPERATING IN THERMOSTAT HIGH / LOW CYCLE (Flashing 3 & 4) This requires purchasing the optional “Wall Thermostat Add-on Kit”. This mode o

Page 21 - DIRECT CONNECTIO

28 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS OPERATING IN THERMOSTAT ON / OFF (Flashing 1 & 2) This also requires purchasing the option

Page 22

29 OOPERATINGPERATING IINSTRUCTIONNSTRUCTION—— LLIGHTINGIGHTING YYOUROUR AAPPLIANCEPPLIANCE Before lighting a fire check to ensure the Burn Grate

Page 23 - Exterior Wall

3 TTABLEABLE OFOF CCONTENTSONTENTS GENERAL INFORMATION MAINTENANCE SAFETY PRECAUTIONS 4 REQUIRED ROUTINE CLEANING 33 SAFETY TE

Page 24 - NSTRUCTIONS

30 OOPERATIONPERATION—— PPERFORMANCEERFORMANCE EENHANCEMENTSNHANCEMENTS A HIGH QUALITY FIRE should burn with a brisk, vibrant, yellow to white col

Page 25

31 FFUELUEL SSPECIFICATIONSPECIFICATIONS——WWOODOOD PPELLETSELLETS The performance of your pellet appliance is greatly affected by the type and q

Page 26

32 FFUELUEL SSPECIFICATIONSPECIFICATIONS——SSHELLEDHELLED CCORNORN The performance of your multi-fuel burning appliance is greatly affected by the

Page 27

33 MMAINTENANCEAINTENANCE——RROUTINEOUTINE CCLEANINGLEANING Proper care of your Glow Boy SERIES pellet appliance is required for peak, sustained

Page 28 - Feed Rates 1 & 2

34 MMAINTENANCEAINTENANCE—— PPERIODICERIODIC CCLEANINGLEANING 1 TON, SEASONAL OR BI-SEASONAL The #1 reason for a service call or unit failing

Page 29

35 FAN MOTORS: Clean the in-take on CONVECTION (ROOM AIR) fan as well as the air holes on the motors of both COMBUSTION and CONVECTION fans annually

Page 30 - Decrease

36 TTROUBLEROUBLE SSHOOTINGHOOTING Proper cleaning, maintenance and the use of clean, dry, quality fuel will prevent the more common stove oper

Page 31

37 TTROUBLEROUBLE SSHOOTINGHOOTING PROBLEM CAUSE SOLUTION Stove Will Not Start (cont….) 4. Air Inlet Damper setting *Check for proper setti

Page 32 - STORAGE

38 TTROUBLEROUBLE SSHOOTINGHOOTING PROBLEM CAUSE SOLUTION Fire burns with a yellow flame. Fuel builds up in the burn grate. Window gets real

Page 33 - EVERY 2 –3 DAYS / WEEKLY

39 OOPTIONALPTIONAL AACCESSORIESCCESSORIES OPTIONAL ITEMS SEE YOUR “Glow Boy” DEALER FOR ADDITIONAL INFORMATION OR TO ORDER. Part No. Descripti

Page 34 - Burn Pot Area

4 SSAFETYAFETY PPRECAUTIONSRECAUTIONS • BEFORE installing or having the pellet appliance installed contact the local building officials to obtain t

Page 35

40 LLIMITEDIMITED WWARRANTYARRANTY Additional Dansons Products www.louisiana-grills.com www.countrysmokers.com Check our website for up to

Page 36 - PROBLEM CAUSE SOLUTION

5 • DO NOT operate the stove if the flame becomes dark and sooty or if the firepot overfills with pellets. Push the OFF Touch Pad and inspect the h

Page 37

6 HHOWOW YYOUROUR AAPPLIANCEPPLIANCE WWORKSORKS Cautions: Do not try to operate your stove with viewing door open. Pellets will not feed under t

Page 38

7 AAUTOMATICUTOMATIC SSAFETYAFETY FFEATURESEATURES L120 LOW LIMIT SWITCH This limit switch is mounted on the exhaust blower housing and has 2 main

Page 39 - CCESSORIES

8 SSPECIFICATIONSPECIFICATIONS HEATING SPECIFICATIONS DIMENSIONS Product subject to Change without notice. ELECTRICAL SPECIFICATIONS

Page 40 - Extended Warranty

9 PPLANNINGLANNING & I& INSTALLATIONNSTALLATION CCHECKHECK LLISTIST Unless you are knowledgeable and experienced in stove installation, we

Modèles reliés GLOW BOY FGB

Commentaires sur ces manuels

Pas de commentaire